Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Arq. bras. oftalmol ; 86(4): 301-307, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447364

ABSTRACT

ABSTRACT Purpose: To evaluate visual outcomes, satisfaction, and quality of life of patients assisted in a Medical School hospital by the Brazilian Public Health System, who underwent bilateral diffractive multifocal intraocular lens implantation. Methods: Case series study with intervention, including 20 patients who underwent bilateral implantation of multifocal IOL EyeDiff® (Eyeol UK, Dunstable, UK). Exclusion criteria were corneal astigmatism >1.5 cylindrical diopters, previous ocular surgery or ocular disease, and intra- or postoperative complications. Patients were evaluated one, three, and six months after surgery. Monocular and binocular visual acuity for distance, intermediate and near, under photopic and mesopic conditions, monocular contrast sensitivity under photopic conditions, defocus curve, and quality of life were assessed. Results: Monocular distance-corrected visual acuity was 0.3 logMAR or better and monocular distance-corrected near visual acuity was J3 or better in all eyes under photopic conditions. Binocular distance-corrected near visual acuity was J1 in all cases. Contrast sensitivity was at the minimum level of normality for low and high spatial frequencies and within normal limits for intermediate spatial frequency. The quality of life questionnaire showed a high level of patient satisfaction. Conclusion: Bilateral implantation of the multifocal intraocular lens EyeDiff® provides patients with good visual acuity and quality of life, besides spectacle independence. The visual acuity and contrast sensitivity progressively improved between one and six postoperative months.


RESUMO Objetivo: Avaliar os resultados visuais, satisfação e qualidade de vida de pacientes atendidos em um hospital escola pelo Sistema Único de Saúde, submetidos a implante bilateral de lente intraocular multifocal difrativa. Métodos: Estudo tipo série de casos com intervenção, incluindo 20 pacientes submetidos a implante bilateral da lente intraocular multifocal difrativa EyeDiff® (Eyeol UK, Dunstable, UK). Os critérios de exclusão foram astigmatismo corneano >1,5 dioptria cilíndrica, cirurgia ou doença ocular prévias e complicações intraoperatórias ou pós-operatórias. Os pacientes foram avaliados após 1, 3 e 6 meses da cirurgia. Foram avaliadas a acuidade visual monocular e binocular para longe, intermediário e perto sob condições fotópica e mesópica, sensibilidade ao contraste monocular sob condições fotópicas, curva de defocus e questionário para avaliação da qualidade de vida. Resultados: A acuidade visual para longe corrigida monocular foi de 0,3 logMAR ou melhor e a acuidade visual para perto com correção para longe foi J3 ou melhor em todos os olhos, sob condições fotópicas. A acuidade visual binocular para perto com a correção para longe foi J1 em todos os casos. A sensibilidade ao contraste estava no nível mínimo de normalidade para frequências espaciais baixas e altas e abaixo dos limites normais para frequência espacial intermediária. O questionário de qualidade de vida mostrou que os pacientes apresentavam altos níveis de satisfação. Conclusão: O implante bilateral da lente intraocular multifocal EyeDiff® proporcionou boa acuidade visual e qualidade de vida, e independência de óculos aos pacientes. A acuidade visual e a sensibilidade ao contraste melhoraram progressivamente entre um e seis meses de pós-operatório.

2.
Arq. bras. oftalmol ; 77(2): 71-75, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-716265

ABSTRACT

Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL) in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR) was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC) was -2.19 (SD: ± 0.53). After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001). Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence. .


Objetivo: Avaliar o resultado pós-operatório de uma nova lente intraocular (LIO) multifocal tórica implantada em pacientes com catarata e astigmatismo corneano. Métodos: Estudo prospectivo não randomizado envolvendo pacientes com catarata, astigmatismo corneano, e motivação para eliminar a dependência dos óculos. Em todos os casos, a lente intraocular tórica Rayner M-flex® T foi implantada dentro do saco capsular. Três meses pós-operatório foram avaliados: acuidade visual para longe, intermediário e perto; equivalente esférico; astigmatismo refracional residual; curva de defocus e sensibilidade ao contraste. Ao final do estudo um questionário referente à satisfação visual foi aplicado. Resultados: Trinta e quatro olhos de 18 pacientes foram incluídos no estudo. Após 3 meses de pós-operatório, a acuidade visual corrigida para longe (logMAR) era de 0,00 ± 0,08 a 6 m, 0,20 ± 0,09 a 70 cm e 0,08 ± 0,11 a 40 cm. A acuidade visual sem correcão foi de 20/40, ou melhor, em 100% dos olhos. A média do cilindro refracional pré-operatório era de -2,19 (DP: ± 0,53). Após o seguimento de 3 meses a média do cilindro refracional era de -0,44 D (DP: ± 0,27) (p<0,001). Os níveis de sensibilidade ao contraste foram elevados. Ao final do seguimento, 87,5% dos pacientes estavam independentes dos óculos para perto, intermediário e para longe, e aproximadamente 44% dos pacientes relatavam halos e glare. Conclusão: O implante de uma lente intraocular multifocal em pacientes com catarata e astigmatismo corneano utilizando a lente intraocular tórica Rayner M-flex® T foi uma opção simples, segura e acurada. Essa nova tecnologia oferece ao cirurgião uma maneira passível de se atingir as expectativas dos pacientes em relação ...


Subject(s)
Aged , Female , Humans , Male , Astigmatism/surgery , Cataract Extraction/methods , Cataract/complications , Lenses, Intraocular , Lens Implantation, Intraocular/methods , Astigmatism/complications , Cataract/physiopathology , Contrast Sensitivity/physiology , Patient Satisfaction , Prospective Studies , Treatment Outcome , Visual Acuity/physiology
3.
Arq. Inst. Penido Burnier ; 33(2): 113-6, jul. 1991. ilus
Article in Portuguese | LILACS | ID: lil-122044

ABSTRACT

Apresentaçäo de dois caso: Doença de Mikulicz e Dacrioadenite aguda, destacando suas características clínicas e o auxílio da ecografia no diagnóstico destas patologias


Subject(s)
Humans , Male , Female , Adult , Dacryocystitis , Mikulicz' Disease , Diagnosis, Differential
4.
Rev. bras. oftalmol ; 46(2): 21-6, abr. 1987. tab
Article in Portuguese | LILACS | ID: lil-39944

ABSTRACT

Foram estudados 1.341 pré-escolares da cidade de Botucatu, com idade de 2 anos à 6 anos e 11 meses, nos meses de abril a junho de l984 com o objetivo de detectar precocemente alteraçöes visuais, estudar sua prevalência e promover seu tratamento imediato. O trabalho desenvolveu-se em três etapas que incluíram esclarecimento aos pais e professores, exame oftalmológico e tratamento das afecçöes encontradas. Foram detectados 4,39% de ametropias, 3,35% de ambliopia, 1,43% de anisometropia, 1,34% de estrabismo e 0,58% de outras afecçöes oculares, como blefarite, catarata, glaucoma e uveíte. Houve necessidade de uso de lentes corretoras em 3,57% das crianças. Ressalta-se ainda que nesta faixa etária há necessidade de pesquisas de campo para abranger maior número de casos, pois apenas 16,1% das crianças de 2 à 6 anos frequentam as pré-escolas de Botucatu


Subject(s)
Child, Preschool , Child , Humans , Male , Female , Eye Diseases/epidemiology , Brazil , Eye Diseases/prevention & control , Eyeglasses
5.
Arq. bras. oftalmol ; 48(5): 160-4, 1985. tab
Article in Portuguese | LILACS | ID: lil-27986

ABSTRACT

Apresenta-se estudo sobre conhecimentos e práticas de 1000 pessoas da cidade de Campinas (SP) em relaçäo a glaucoma, ambliopia, estrabismo, conjuntivite e acidentes oculares, quanto ao problema em si e sua prevençäo. Realizam-se entrevistas, de forma aleatória, com 200 pessoas no "campus" da Universidade de Campinas e 800 transeuntes no centro da cidade. Conclui-se pela insuficiência de conhecimentos e existência de conceitos e práticas errôneas sobre os aspectos abordados, recomendam-se o desenvolvimento de programas de educaçäo em saúde para prevençäo de distúrbios visuais e a realizaçäo de pesquisas no campo da oftalmologia sanitária


Subject(s)
Adolescent , Adult , Middle Aged , Humans , Eye Diseases/prevention & control , Preventive Health Services , Age Factors , Brazil
SELECTION OF CITATIONS
SEARCH DETAIL